Skip to main navigation Skip to main content

CEEM : Clinical and Experimental Emergency Medicine

OPEN ACCESS
ABOUT
BROWSE ARTICLES
FOR CONTRIBUTORS

Articles

Original Article
AI & Digital Health | Cardiovascular

Pilot Evaluation of a Novel Artificial Intelligence (AI) Heart Rate Variability (HRV)-Guided Risk Stratification for Chest Pain in the Emergency Department: A Randomized Controlled Trial

Yiteng Wang1, Ruiqi Li2, Yogeswary Pasupathi3, Yiling Chan3, Priscilla Isabel Birthylon3, Stephanie Fook-Chong1, Helen Zhang3, Swee Han Lim3, Kenneth Tan Boon Kiat3, Pamela Isa Basilio-Razon3
Available online: July 27, 2026
1Prehospital Emergency Research Centre, Duke-NUS Medical School, Singapore
2Lee Kong Chian School of Medicine, Nanyang Technological University, Singapore
3Department of Emergency Medicine, Singapore General Hospital, Singapore
Corresponding author:  Pamela Isa Basilio-Razon,
Email: pamela.isa.evangelista.basilio@sgh.com.sg
Received: 28 January 2026   • Revised: 20 April 2026   • Accepted: 26 April 2026
  • 1,240 Views
  • 78 Download
  • 0 Crossref
  • 0 Scopus

Background
Heart rate variability (HRV) analysis powered by artificial intelligence (AI) offers a rapid, non-invasive, and objective approach for acute coronary syndrome (ACS) risk stratification in the emergency department (ED). The objective of this study was to evaluate the feasibility and impact of aiTriage™, an AI HRV-guided tool for chest pain triage, compared with standard care.
Methods
In this single-blinded randomized controlled trial, 560 ED patients with suspected ACS underwent 5- minute ECG monitoring for HRV analysis, which generated a 0–100 risk score and triage recommendations (high, medium, or low risk). Patients were randomized to standard care (control) or an HRV-guided protocol (intervention). Physicians in the control group were blinded to HRV results.
Results
Of 426 analysed patients (mean age 54 ± 13 years, 35% female, 16.2% prior MI), the HRV-guided protocol reduced hospital admissions (50.2% vs 61.1%; risk difference -10.9 percentage points, 95% CI: -20.1 to -1.8) and serial cardiac enzyme testing (32.1% vs 41.7%; risk difference -9.6 percentage points, 95% CI: -18.4 to -0.9) compared with standard care. Among discharged patients, the median ED length of stay was 20 minutes shorter in the intervention group (95% CI: -45 minutes to 3 minutes). The overall 30-day MACE rate was 9.5%, with no events among discharged patients.
Conclusion
A rapid AI HRV-guided risk stratification tool was feasible to deploy, and has potential to reduce serial cardiac enzyme testing, ED LOS and hospital admissions. An adequately powered RCT is needed to confirm these findings and assess clinical safety. This trial is registered at ClinicalTrials.gov (NCT07074808).

Download Citation

Download a citation file in RIS format that can be imported by all major citation management software, including EndNote, ProCite, RefWorks, and Reference Manager.

Format:

Include:

Pilot Evaluation of a Novel Artificial Intelligence (AI) Heart Rate Variability (HRV)-Guided Risk Stratification for Chest Pain in the Emergency Department: A Randomized Controlled Trial
Download Citation

Download a citation file in RIS format that can be imported by all major citation management software, including EndNote, ProCite, RefWorks, and Reference Manager.

Format:
Include:
Pilot Evaluation of a Novel Artificial Intelligence (AI) Heart Rate Variability (HRV)-Guided Risk Stratification for Chest Pain in the Emergency Department: A Randomized Controlled Trial
Close